Fan / Light Combination Switch Wiring

Switched Together

3 Way Switch3 Way SwitchFan Light Combination Fixture

3 Way Switches
Power at Fixture

Printer Friendly Version of Article

WHILE EXTREME CARE HAS BEEN IMPLEMENTED IN THE PREPARATION OF THIS SELF-HELP DOCUMENT, THE AUTHOR AND/OR PROVIDERS OF THIS DOCUMENT ASSUMES NO RESPONSIBILITY FOR ERRORS OR OMISSIONS, NOR IS ANY LIABILITY ASSUMED FROM THE USE OF THE INFORMATION, CONTAINED IN THIS DOCUMENT, BY THE AUTHOR and / OR PROVIDER.

Read the legal disclaimer page - click the legal link in the menu above

Fan Light combination Fixture with power at fixture using 3 way switches

 

Fan Light combination Fixture with power at fixture using 3 way switches

Connections Instructions:
(as depicted in the diagrams above)

At the Fixture box...

Two cables entering this box, one is the circuit power supply cable, the other cable (wire cable # 1) coming from switch 1.

* a) connect the black wire from the 'circuit power supply' cable to the white wire of the cable coming from switch 1.
* b) using an insulated wire nut connect / join the black wire from switch 1 + the switched ungrounded conductor (hot) from light (shown as black in diagram) + the switched ungrounded conductor (hot) from fan (shown as red in diagram)
* c) connect the white wire from the 'circuit power supply' cable to the grounded conductor (neutral) of fixture (shown as white in diagram)
* d) please see under important notes in regards to the equipment grounding conductor (bare wire).

At switch 1 box...

Two cables entering this box, one is coming from the fixture , the other cable coming from switch 2.

* a) using an insulated wire nut connect / join the white wire coming from fixture + the black wire of cable coming from switch 2.
* b) connect the black wire coming from fixture to the common screw of switch 1.
* c) connect the white wire coming from switch 2 to one of the remaining main screws of switch 1.
* d) connect the red wire coming from switch 2 to the last remaining main screw of switch 1.
* e) please see under important notes in regards to the equipment grounding conductor (bare wire).

At switch 2 box...

One cables entering this box coming from switch 1.

* a) connect the black wire coming from switch 1 to the common screw of switch 2.
* b) connect the white wire coming from switch 1 to one of the remaining main screws of switch 2.
* c) connect the red wire coming from switch 1 to one of the last  remaining main screws of switch 2.
* d) please see under important notes in regards to the equipment grounding conductor (bare wire).

Important Notes:

By electrical codes you MUST have at least 6 inches of wire in the electrical box itself, and also the wire must be able to reach at least 3 inches outside the box, it can fail an electrical inspection if the required min. wire length is not met.  You may have the wires a bit longer (within reason) but they cannot be shorter. Also see the note on box fill further down in this article.

You are allowed to re-designate a white wire  to be used as a hot (ungrounded conductor) in switch circuits but in those cases where a white wire is used in this manner, you must wrap a piece of black electrical tape around that white wire inside the box  to signify that is being used as an ungrounded (hot) conductor.

You cannot re-designate a white wire that is actually connected to the light fixture itself. At the fixture itself, the white wire must be the grounded conductor (neutral) coming from the circuit power supply cable.

In the 3 way configuration depicted on this page, the white wire coming from the fixture to switch 1 and the white wire going from switch 1 to switch 2 have been used to carry a switched ungrounded conductor (hot) part of the circuit and therefore as stated should have a piece of black electrical tape wrapped around the wire in the box. The white wire from the power supply cable that goes to the fixture itself at the fixture box location is a grounded conductor (neutral) and therefore is left as white with NO black tape on it.

Use wire nuts of the correct size to join wires together.  For fan / light combination fixtures, most likely it will have wire connections, the white wire will be the grounded conductor (neutral), any green wires are equipment grounding conductors, then there will be two other wires one will be the switched ungrounded conductor (hot) for the light, and one will be the switched ungrounded conductor (hot) for the fan. If you are confused please post to our forums for further clarification.

The wire cable running between switch 1 and switch 2 has 3 wires in it - black / red / white (plus the bare equipment grounding  wire).

What is not shown in the drawings to avoid confusion, is that each wire cable also has a bare equipment grounding wire included. This wire is connected to a grounding screw in each electrical box (if the box is metal),  joined either through the grounding screws in the box itself or via a wire nut to the bare wire of the next cable entering / exiting the box, it is also connected to any grounding screw (if there is one) on the switch itself, as well as any grounding screw at the fixture (green wires that attach to the fixture are grounds).  Now if using a plastic box, it is made of a material that is non conductive, however some plastic boxes have a metal strip inside that can still be used to connect equipment grounding wires, in the event that it does not use wire nuts to join the bare grounding wires together. The equipment grounding wire (bare in most cables) must be electrical conductively joined throughout the circuit.  Green wires are also equipment grounding conductors.

At the switch itself there are 3 main electrical screws, one of these 3 screws is distinctly different in color (perhaps darker) than the other 2. This screw connection is called the common screw. It is very important that in order for the 2 switches to work as they are intended to that the correct wire is attached to the common screw.  Basically as depicted in the drawings one switch has the ungrounded conductor (hot) from the circuit power supply cable attached to the common screw, where the other switch had the ungrounded conductor (hot) feed to the light fixture itself.

Please also note that there are a variety of manufactures out there that make 3 way switches so it is possible that the switch you buy may have the common screw located in a different spot or side of the switch then depicted in the drawings in this article, just make sure that the wire depicted to go to the common screw of each of the switches is actually connected to the common screw of the 3 way switch you bought. The other 2 wires going between the remaining screws of one switch to the other switch does not matter as long as one wire of the 2 remaining wires go on each of the remaining 2 screws of the screw.

If there is an equipment grounding screw on the 3 way switch it may be green in color and be separated away from the main connections of the switch and likely part of the metal frame that is also part of the mounting structure of the switch.


Extensions to this Switch circuit...

Be Aware that there is a limit by code on how many wires can be in a given size electrical box, when adding more wires to the same box you may have to install a larger and / or deeper box to allow space for more wires coming and out of the box.

Here is an article / explanation in regards to box fill calculations 'Box Fill Calculation'

The instructions here are based on the fact that the circuit has already been wired to the configuration shown in this article and we are now making the wiring changes for onward power.

From the switch locations....

No onward connections are possible from either of the switch locations because a grounded conductor (neutral) does not exist with this configuration  at these locations.

From the fixture location...

Onward 'always on circuit power' and 'switched power' is possible from the fixture location.

Option 1: Onward Always On Circuit Power...
(showing bellow the fixture portion of the circuit)

Onward Always On Power from Fixture

Not shown in the diagram but the onward cable also has a bare wire (equipment grounding conductor) that also must be connected to all the other bare wires at the fixture electrical box.

Connection Instructions for onward cable (always on state)

* a) Using an insulated wire nut, attach / join - the white wire of onward cable + the white wire from the 'circuit power supply cable' +the  white wire connected to the grounded conductor (neutral) of fixture.
* b) Using an insulated wire nut, attach / join - the black wire of onward cable + the black wire coming from the 'circuit power supply cable' + the white wire coming from switch.

Identification of wires of onward wire cable...

Black - Ungrounded conductor (hot - always on)
White - grounded conductor (neutral)

**************************************

Option 2: Onward switched power...
(showing bellow the fixture portion of the circuit)

Onward Switched Power from Fixture

Not shown in the diagram but the onward cable also has a bare wire (equipment grounding conductor) that also must be connected to all the other bare wires at the fixture electrical box.

Connection Instructions for onward cable (switched)

* a) Using an insulated wire nut, attach / join the white wire of onward cable + the white wire coming from the 'circuit power supply cable' + the white wire connected to the grounded conductor (neutral) of fixture.
* b) Using an insulated wire nut, attach / join the black wire of onward cable + the black wire coming from switch + the switched ungrounded conductor (hot) of light (shown as black in diagram) + the switched ungrounded conductor (hot) of fan (shown as red in diagram)

Identification of wires of onward wire cable...

Black - Switched ungrounded conductor (hot - switched)
White - grounded conductor (neutral)

**************************************

Option 3: Onward switched & always on power...
(showing bellow the fixture portion of the circuit)

Onward Always On and Switched Power from Fixture

Not shown in the diagram but the onward cable also has a bare wire (equipment grounding conductor) that also must be connected to all the other bare wires at the fixture electrical box.

Connection Instructions for onward cable (switched & always on)

* a) Using an insulated wire nut, attach / join the white wire of onward cable + the white wire coming from the 'circuit power supply cable' + the white wire connected to the grounded conductor (neutral) of fixture.
* b) Using an insulated wire nut, attach / join the black wire of onward cable + the black wire coming from switch + the switched ungrounded conductor (hot) of light (shown as black in diagram) + the switched ungrounded conductor (hot) of fan (shown as red in diagram)
* c) Using an insulated wire nut connect / join the red wire of onward cable + the black wire coming from the 'circuit power supply' cable + the white wire coming from switch.

Identification of wires of onward wire cable...

Black - Switched ungrounded conductor (hot - switched)
Red - Ungrounded conductor (hot - always on)
White - grounded conductor (neutral)


Foreign Users:

The colors of the wires depicted are based on the standards and code requirements / configuration in the United States and Canada. If you are viewing this site from a foreign country, your wiring standards and color of wires may be different but the principal and sequence of wiring will still remain the same. Therefore the information in this article may still be of use to you regardless of what country you may be in. Just translate the colors used here to the color of wires used in your country in regards to ungrounded (hot) conductors  / grounded conductors (neutral) and equipment grounding conductors as well know applicable code requirements in your country.

Written: Jan. 4, 2012
Revised: June 25, 2013
Proof Read / Released: July 15, 2013
Diagrams redrawn with Transparency: Jan. 14, 2014
By: Donald Kerr

QUICK MENU 

Home (Wiring Done Right)
2011 NEC New Rule 'Switch Connections'
3 Way Switch
4 Way Switch
Accessory Buildings
Adding Outlet
Aluminium Wiring
Arc Circuit Protection
Backup Generators / Transfer Switches
Basic Switch
Box Fill Calculations
Breaker Circuit Types
Conduit Fill
Convert Pull String to Wall Switch
Definitions
Doorbell System / Wiring
Dryer Outlet
Electrical Box Types
Electrical Dangers
Electrical Safety
Electricity, What is It?
Fan / Light Combo
Switched Together  
IF you require 2011 NEC 404.2 (C) compliant options then re-select by clicking on menu above.
IF 2011 NEC 404.2 (C) does NOT apply -  Options LIST
Power at Switch
Power at Fixture
3 Way Switches, Power Source at Fixture
3 way switches, power source and fan/light combo power feed from same switch box
3 way switches, power source at one switch / fixture feed from other switch
3 way switches, power at fixture, 3 wire  cable being routed thru the ceiling box between switches
3 way switches, power at switch, 3 wire cable being routed thru the ceiling box onward to other switch
Switched Separately  
Fan Always Hot / Light Switched  
Generation / Distribution Grid
GFI Outlets
Home Electrical Design
Main Electrical Panel
Multiple Fixture Wiring
Old Home / Wiring
Outlet, Half Switched
Range Outlet
Series Switches
Split Circuit Outlet
Sub Panel
Switch Outlet Types
Testing Equipment
Tools, Basic Tools
Trouble Shooting
Wire Cable Types
Wire Connections
Wire Routing Basics
Work Shop Wiring
World, Electricity around the

Copyright 2014 +
All Rights Reserved
Donald Kerr / Wiring Done Right
http://www.wiringdoneright.com/